- Measuring method: infrared spectroscopic
- Measured variable: surface weight of lubricant layer in g/m²
- Measuring range: 0.3 - 6 g/m²; > 0.02 g/m² possible with special calibration
- High measuring accuracy
- Repetition accuracy: +/- 5 mg/m2 without smoothing (120 Hz) and +/- 0.8 mg/m2 with smoothing
- Measuring resolution: 0.01 g/m²
- Lubricants: mineral oil, thixotropic mineral oil, hot melts, waxes, other organic lubricants after special calibration
- Operating distance (measuring position): 200 mm (traversing)
- Strip height deviations: +/- 20 mm
- Ambient temperature: +5 °C up to +55 °C (extended temperature range with cooling possible)
- Measuring frequency: 120 Hz
- Traversing speed: 0.5 m/sec adjustable
- Cleaning intervals: up to 12 months (depending on environment)